Non-Curing Multi-Purpose Sealant Check Seal™ HTS Pak

logo-socoCheck Seal™ HTS Pak is a heavily fibrous sealant designed to seal valves, valves packing and valve bonnets at temperatures up to +371°C. HTS PAK works great for a wide variety of leaks with its fibrous characteristics, such as leaking valve seats, this sealing is accomplished without affecting valve operation. Other uses include steam valve packings, steam union leaks, steam wire wraps and steam valve bonnets.

Applications : aliphatic hydrocarbons, asphalt, hot oil, steam and geothermal water; good general use for sealing valves
The exact scope of sealant´s application suitability refer to compatibility chart.
Temperature range : from -6°C to +371°C
Limitations : do not use above +371°C; Do not use on oxygen services.
Appearance : dark gray fiborous sticks
Penetration (ASTM D217) : 70-80
Injection characteristics : it flows well at a filling pressure of 34.5 bar; flows well with minimum hydraulic pressure;
Cure : slight cure at higher temperatures
Long-term changes : some loss of carrier with pressure and temperature; reinjection may be required
Storage : in a dry place at room temperature
Shelf life : 2 years
Packaging : 3.5cm x 21.6cm J sticks or 1.9cm x 10.1cm plugs

The sealant is suitable only for industrial use by trained personnel according to the local regulations and employer requirements. Always read the Safety Data Sheet (SDS), technical data sheet and warranty conditions before use. For information on the chemicals and conditions regarding health and safety during handling, storage, use and disposal, refer to the relevant SDS supplied with the material, or available upon request.

The application suitability of the material use for a particular chemical composition of the medium is given in the compatibility chart eventually in chemical resistance tables for respective material. Chemical resistance (compatibility chart) tables are available upon request or as online version at our website (tables).

Some chemical additives contained in steam or boiler feed water may prevent curing of the sealant.

We recommend consulting the usage of particular selants with us before the use. In case you are not certain about the choice for particular sealant, please contact us or our nearest representative. We will prepare a solution tailored to your needs! ... (Contact Us.)
More information
Do not hesitate to contactus:
If you need more information, please send us an e-mail and our colleague will reply you by return. Thank you.